Thermo-Gravimetric & Differential Thermal Analyzer (TG-DTA)
|
|
Measurement temp. range: Room tem. ~ 1500 ¡É
Max heating rate: 100 ¡É/min
Max measurement sample quantity: 1 g
TG measurement range: ± 0.1 ~ ± 250 mg/F.S.
DTA measurement range; ± 1.5 ~ ± 1000 §Å/F.S. |
|
The TG-DTA is a simultaneous measurement instrument combining TG, which utilizes a horizontal differential type balance beam, with the highly flexible DTA feature. |
|
Microscopy
|
|
Zoom Stereo
Magnificcation : ¡Ä ~ ×2400
Metal Optical
Eyepieces : KHW 10 × 20 mm field of view
Objectives : S.PLAN MET 4×, 10×, 20×, 40× |
|
These equipments are used to observe the surface morphology of glass and ceramic complex from low magnification to the bitter cup rate. |
|
Withstanding Voltage Tester
|
|
Testing Voltage: AC/DC 0~5kV/10kV
Current Detecting: 0.1~55mA(AC) 0.1~5.5mA(DC)
Testing Time: 0.5~999 sec
Generating Power Capacity: 500VA |
|
This equipment is an exclusive tester for withstanding voltage test. |
|
UV-Spectrometer
|
|
Wavelength Range: 190 to 900nm
Resolution: 0.1nm
Wavelength Accuracy: ±0.3nm
Wavelength Repeatability: ±0.01nm |
|
This equipment is used to evaluate Reflectance, Transmittance, Absorbancy of materials. |
|
FT-IR Spectrometer
|
|
Optical System: Single beam optics
Wavenumber range:
7,800 cm ~ 350 cm-1
12,500 cm ~ 240 cm-1(Optional) |
|
Infrared (IR) spectroscopy is a chemical analytical technique, which measures the infrared intensity versus wavelength (wavenumber) of light. Based upon the wavenumber, infrared light can be categorized as far infrared (4 ~ 400cm-1), mid infrared (400 ~ 4,000cm-1) and near infrared (4,000 ~ 14,000cm-1). |
|
Dilatometer
|
|
Temperature range: up to +1400¡É
Sample length: up to 50mm
Measuring range:100§ up to 5000 § |
|
This equipment is used to evaluate CTE(Coefficient of Thermal Expansion) of materials |
|
Glass Softening Point Determination System
|
|
Fiber
Max Temp.: 1000¡É
Heating Element: KT A-1 Molding Heater
Average Heating Rate: User freely
Bulk
Max Temp.: 1000¡É
Heating Element: Nichrome 500watts
Average Heating Rate: 25 ¡É/min |
|
These equipments are designed for quick and simple evaluation of glass softening point. |
|
Hot Stage Microscopy
|
|
This equipment is an essential in situ characterization and monitoring technique with wide applications in different areas of materials science.
Especially It can be used to predict Fusion behavior of materials. |
|
|
|
Multi-Wavelength Abbe Refractometer
|
|
Measuremnt Range
Reflectance :
1.5164 ~ 1.9164 (459nm)
1.4700 ~ 1.8700 (standard, 589nm)
1.4558 ~ 1.8557 (680nm)
1.4304 ~ 1.8303 (1100nm)
Measurement Accuracy : ±0.0002 |
|
This equipment is used to evaluate reflectance of materials with multi-wavelength. |
|
Solar simulator
|
|
The solar-simulator is used to measure the solar cell parameters of not only modules but also cells.
|
|
|
|
|
|